Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| Type: | Metal Film Displacement Sensors |
| Output Signal Type: | Analog Type |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
![]() |
|||||
| System Abbreviation | Φ 5 system or 5mm system |
Φ 8 system or 8mm system |
Φ 11 system or 11mm system |
Φ 18 system or 18mm system |
Φ 25 system or 25mm system |
| Model | CWY-D0-401 | CWY-D0-402 | CWY-D0-404 | CWY-D0-410-18 | CWY-D0-410-25 |
| Measuring and Electrical Properties | |||||
| Measurement Principle | Eddy current principle | ||||
| Calibrating Target Disc Materials | 45# Steel | ||||
| Standard Range | 1. 5 mm | 2mm | 4 mm | 10mm | 10mm |
| Standard Measuring Range | 0. 25-1. 75mm | 0.5-2.5mm | l-5mm | 0. 5-10. 5mm | 1 -11 mm |
| Customisable Maximum Range | 2mm | 3 mm | 6 mm | 10mm | 16mm |
| Standard Sensitivity | 8mV/um | 8mV/um | 4mV/um | 0.8mV/um | 0. 8mV/um |
| Sensitivity Error | ≤ ±2% | ≤ ±3% | ≤ ±l% | ||
| Sensitivity Interchangeability Error 1) | ≤ ±5% | ≤ ±3% | |||
| Non-linearity | <1% | <1. 5% | |||
| Resolution | ±l um | ±l um | ±2 um | ±10 um | ±10 um |
| Frequency Response | DC to 10kHz (-3dB) | DC to 3kHz(-3dB) | DC to 1kHz(-3dB) | ||
| Output Signal Range Corresponding to Range | -2 to -14V | -2 to -18V | -2 to -18V | -2 to -10V | -2 to -10V |
| Max. Output Voltage | -23 V | ||||
| Output Resistance | 100Ω | ||||
| System Temperature Drift | ±3% F. S. (-20°C to +80°C) | ||||
| Recommended Installation Voltage | -10V | -6V | |||
| Front-end Power Supply | -24VDC±10% | ||||
| Maximum Current Consumption | ≤ -20mA | ||||
| Probe Resistance | 8.2±0.3Ω | 4.9±0. 3Ω | 6.5±0.3Ω | 4.2±0. 2Ω | 0. 9±0.3Ω |
| Protection Classes | |||||
| Probe and Extension Cable Operating Temp. | -40°C to +170°C | ||||
| Front-loader Operating Temp. | -40°C to +80°C | ||||
| Probe Protection Classes | IP68 | ||||
| Front-loader Protection Classes | IP40 | ||||
| Electromagnetic Compatibility Specification | EN61000-6-2, EN61000-6-4 | ||||
| Physical Properties | |||||
| Probe Protection Cover Material | PPS | PEEK | |||
| Probe Protection Cover Diameter | 5. 5mm | 8. 4mm | 11. 2mm | 16. 7mm | 27. 0mm |
| Probe Screw Material | Stainless steel | ||||
| Probe Screw Thread Specification|Customizable | M8 or M10 | M10 | M14 | M20 (custom M18 available) | M30 |
| Probe Cables and Extension Cables | Three-core coaxial cable | ||||
| Cable Length | Probe cable + extension cable = 5m or 9m (Customisable ) | ||||
| Cable Sheathing Materials | FEP | ||||
| Min. Turning Radius of Cable | 30mm | ||||
| Front-loader Material | ADC12(Die-cast aluminium alloy) | ||||
| Total System Weight | 500g±3% | 700g±3% | |||
| Remarks | 1) Sensitivity interchangeability error refers to the interchangeability of any component for comparison with the standard sensitivity. | ||||